CJX2-F three phase electrical AC Magnetic Contactor price 2018-11-16T14:26:30+00:00

Project Description

LC1-F three phase contactor

CJX2-F three phase electrical AC Magnetic Contactor price

CJX2-F three phase electrical AC Magnetic Contactor price  is stuitable for circuit of rated current up to 800A, rated voltage up to 380V, 50/60Hz; remotely breaking , starting and controlling electric motors;controlling the distribution circuits of rated current from 115A to 800A. It conforms to IEC60947-4-1

LC1-F three phase contactor dimension photo

ac contactor dimension drawing
CJX2- a G G min. G max. J1 Q Q1
F630 2P 309 180 100 195 68.5 102 127
F630,F800 3P 309 180 100 195 68.5 60 89
F630 4P 389 240 150 275 68.5 60 89
magnetic contactor dimension drawing

Bobbin of CJX2-F ac contactor 

Type Used for Contactor
LX1-FF CJX2-F115-F150
LX1-FG CJX2-F185-F225
LX1-FH CJX2-F265-F330
LX1-FJ CJX2-F400
LX1-FK CJX2-F500
LX1-FL CJX2-F630
LX1-FK(1) CJX2-F780

LC1-F electrical contactor specification and Main Technical Parameters

Type Rated operational current AC-3(A) Max power rating of 3-phase motors in category AC-3(KW) Operating frequency (time/hour) AC-3 Electrical life AC-3X104 Mechanicalife x104
220V    230V 380V    400V 415V 440V 500V 660V   690V 1000V
CJX2-F115 115 30 55 59 59 75 80 65 1200 120 1000
CJX2-F1154 115 30 55 59 59 75 80 65 1200 120 1000
CJX2-F150 150 40 75 80 80 90 100 65 1200 120 1000
CJX2-F1504 150 40 75 80 80 90 100 65 1200 120 1000
CJX2-F185 185 55 90 100 100 110 110 100 600 100 600
CJX2-F1854 185 55 90 100 100 110 110 100 600 100 600
CJX2-F225 225 63 110 110 110 130 129 100 600 100 600
CJX2-F2254 225 63 110 110 110 130 129 100 600 100 600
CJX2-F265 265 75 132 140 140 160 160 147 600 80 600
CJX2-F2654 265 75 132 140 140 160 160 147 600 80 600
CJX2-F330 330 100 160 180 200 200 220 160 600 80 600
CJX2-F3304 330 100 160 180 200 200 220 160 600 80 600
CJX2-F400 400 110 200 220 250 257 280 185 600 80 600
CJX2-F4004 400 110 200 220 250 257 280 185 600 80 600
CJX2-F500 500 147 250 280 295 355 335 335 600 80 600
CJX2-F5004 500 147 250 280 295 355 335 335 600 80 600
CJX2-F630 630 200 335 375 400 400 450 450 600 80 600
CJX2-F6304 630 200 335 375 400 400 450 450 600 80 600
CJX2-F780 780 220 400 425 425 450 475 450 600 80 600
CJX2-F7804 780 220 400 425 425 450 475 450 600 80 600
CJX2-F800 800 250 450 450 450 450 470 450 600 80 600

Contactor installation and outline dimension

LC1-F115 contactor installation dimension
CJX2- a b b1 b2 c f G G1 J J1 L M P Q Q1 S I Y
F115 3P 163.5 162 137 265 171 131 106 80 106 120 107 147 37 30 60 20 26 13.5
4P 200.5 162 137 265 171 131 143 80 106 120 107 147 37 30 60 20 26 13.5
F150 3P 163.5 170 137 301 171 131 106 80 106 120 107 150 40 26 57.5 20 34 13.5
4P 200.5 170 137 301 171 131 143 80 106 120 107 150 40 26 57.5 20 34 13.5
F185 3P 168.5 174 137 305 181 130 111 80 106 120 13.5 154 40 29 59.5 20 34 13.5
4P 208.5 174 137 305 181 130 151 80 106 120 114 154 40 29 59.5 20 34 13.5
F225 3P 168.5 197 137 364 181 130 111 80 106 120 114 172 48 21 51.5 25 45 13.5
4P 208.5 197 137 364 181 130 151 80 106 120 114 172 48 17 47.5 25 45 13.5
F265 3P 201.5 203 145 375 213 147 142 96 106 120 141 178 48 39 66.5 25 45 21.5
4P 244.5 203 145 375 213 147 190 96 106 120 141 178 48 34 66.5 25 45 21.5
F330 3P 213 206 145 375 219 147 154.5 96 106 120 145 181 48 43 74 25 45 20.5
4P 261 206 145 375 219 147 202.5 96 106 120 145 181 48 43 74 25 45 20.5
f=minimum distance required for coil removal
LC1-F ac contactor outline mounting
CJX2- a b b2 c f G G min. G max. G1 G1 min. G1 max. J L M P Q Q1 S
F400 2P 213 206 375 219 119 80 66 102 170 156 192 19.5 145 181 48 69 96 25
3P 213 206 375 219 119 80 66 102 170 156 192 19.5 145 181 48 43 74 25
4P 261 206 375 219 119 80 66 150 170 156 240 67.5 145 181 48 43 74 25
F500 2P 233 238 400 232 141 80 66 120 170 156 210 39.5 146 208 55 76 102 30
3P 233 238 400 232 141 80 66 120 170 156 210 39.5 146 208 55 46 77 30
4P 288 238 400 232 141 140 66 175 230 156 265 34.5 146 208 55 46 77 30