LC1-F lc1-d 1300A 3 pole electromagnetic ac contactor wiring switch 2019-08-19T14:24:45+00:00

Project Description

CJX2-F1300 ac contactor

LC1-F lc1-d 1300A 3 pole electromagnetic ac contactor wiring switch

LC1-F lc1-d 1300A 3 pole electromagnetic ac contactor wiring switch is for long distance breaking and closing the circuit and frequently starting and control ac motor. Its rated current can be up to 2750A. And it can connect with appropriate thermal overload relays composition electromagnetic starter to protect the possible over load operation of the circuit, and can also connect other auxiliary parts of reversible conversion with mechanical interlock contactor, power distribution conversion of contactor. It confroms to IEC60947-4-1

LC1-F 1300 to 3200 ac contactor

Model Confroming to GB14048.4 standard CJX2-F700 CJX2-F850 CJX2-F1050 CJX2-F1300
Environment
Rated insulation voltage(Ui) V 1000 1000 1000 1000
Rated Impulse withstand voltage(Ue) KV 8 8 8 8
Rated operational voltage (Ue) V 1000 1000 1000 1000
Operational Power frequency range                                                         HZ            16—–200
Standards GB14048, IEC60947, EN60947
Ambient air temprature storage -60–+80
running -5—+55
under rated voltage -40–+70
Maximum operating altitude m 2000
permitted altitude m 2000
Humidity + 40℃ relative humidity less than 50%, below 40 ℃ maximum humidity less than 90%
Impulse withstand capacity 1/2 sinewave=11ms contactor opening 6gn 6gn 6gn 6gn
contactor closing 15gn 15gn 15gn 15gn
Shock and vibration resistance…150Hz contactor opening 1.5gn 2gn 2gn 2gn
contactor closing 5gn 4gn 4gn 4gn
Degree of pollution Pollution degree III
Protection degree Main circuit IP00
coil terminal IP20 avoid direct contact with the finger
Operating frequency cycles/hour 600 600 600 600
Operating position without derating ±300 ( in relation to normal mounting plane)
Control circuit characteristics  (rated control voltage) AC V 110-660
DC 110-500
control voltage limits (≤55℃) Operating voltage V 0.85-1.1Uc
Drop-out voltage(AC) V 0.2-0.75Uc
Drop-out voltage(DC) V 0.1-0.75Uc
Average consumption Inrush (AC) VA 1150 1150 1730 1730
Sealer (AC) VA 18 20 25 25
Inrush (DC) W 1140 1220 1920 1920
Sealer (DC) W 7.5 8 12.5 12.5
Operating time closing ms 40-75
opening(AC) ms 100-170
opening(DC) ms 45-60
Mechanical durability (under Uc) 106 3 3 3 3 3
Notes: for other installation methods, does not guarantee the contactor related performance
CJX2-F1450 CJX2-F1700 CJX2-F2100 CJX2-F2600 CJX2-F3200
1000 1000 1000 1000 1000
8 8 8 8 8
1000 1000 1000 1000 1000
Maximum relative humidity less than 90% below 20℃
6gn 6gn 6gn 6gn 6gn
15gn 15gn 15gn 15gn 15gn
2gn 2gn 2gn 2gn 2gn
4gn 4gn 4gn 4gn 4gn
600 600 600 600 600
2200 2200 2200 3000 3000
40 40 40 50 50
2200 2200 2200 3000 3000
16 16 16 20 20
3 3 3 2 2
Ac contactor dimension diagram
LC1-F1300 ac contactor drawing photo
CJX2-F1450 CJX2-F1700 CJX2-F2100 CJX2-F2600 CJX2-F3200
1450 1700 2100 2600 3200
1000 1000 1000 1000 1000
16-200 16-200 16-200 16-200 16-200
1450 1700 2100 2600 3200
2175 2550 3150 3900 4800
9000 10000 11500 13000 14800
6800 7500 8500 9950 11000
4900 5500 6400 7700 8950
3700 4200 4800 5800 6900
2700 3000 3600 4260 5400
2 2 2 3 3
0.083 0.071 0.057 0.046 0.037
175 205 250 310 380
2 3 4 3 3
100X5 100X5 100X5 100X10 100X10
4-12 4-12 4-12 4-12 4-12
58 58 58 58 58
Used in circuit of AC 50/60Hz, voltage up to 1000V ,current up to 3200A, controlling resistance , noninductive, slightly inductive loads, distribution circuits
Rated operational current A Le AC1(Ue 380V) 700 850 1050 1300
Conventional thermal current A Ith =40℃  (Ue 380V) 700 850 1050 1300
Rated operational voltage (Ue)max Max 1000 1000 1000 1000
Number of poles(NO) 2\3 2\3 2\3 2\3
Maximum operating power KW 3-phases ≤40℃   AC1,50Hz 220/240V 240 295 360 450
380/400V 420 510 630 780
440V 470 570 700 870
500V 520 630 780 960
660/690V 685 830 1030 1270
1000V 1035 1260 1550 1920
Short-circuit protection by fuse Type “2” type RSG-3 RSG-3 RSG-3 RSG-3
specification 1100 1100 1100 1100
Optional parts Instantaneous auxiliary contact: ZTCF3\ Time delay auxiliary contact: ZYCST\ZTCSR protection from dust /mosit: LADX
Contactor CJX2-F700 CJX2-F850 CJX2-F1050 CJX2-F1300
Weight(Kg) 8.9 11.7 17.3 18.6
Serial number 3-poles 1041 0142 0143 0144
2-poles 0146 0147 0148 0149
Type CJX2-F700 CJX2-F850 CJX2-F1050 CJX2-F1300
Rated operational current A     Ue≤ 400V AC1 A 700 850 1050 1300
Rated operational voltage Ue Max V 1000 1000 1000 1000
Frequency limits of the operation current Hz 16-200 16-200 16-200 16-200
Conventional thermal current ≤  40℃ A 700 850 1050 1300
Making capacity 1 rms conforming  GB14048.4 A 1050 1275 1575 1950
Breaking capacity A Turn on the breaking current 1.5X1 (AC1)
Short-ciruit rating cold state  ≤  40℃ 10 secs A 4200 5100 6300 7800
30 secs A 3360 4080 5040 6240
1 min A 2100 2550 3150 3900
3 min A 1680 2040 2520 3120
10 min A 1260 1530 1890 2340
Each paralle out numbers 2 2 2 2
Average impdeance per pole MQ 0.17 0.14 0.12 0.096
Power dissipation per pole for the above operational currents AC1(Ue≤ 400V) W 85 100 120 150
Wiring can match wire cut off number of bars 2 2 2 2
dimensions of bars mm2 50X5 50X5 80X5 100X5
bolts diameter Number -Φ mm 1-12 1-12 3-12 3-12
Tightenning torque circuit connection N.m 58 58 58 58
Contactors Rated operational current AC1 A Maximum operational power AC1 3 phases W Weight (Kg) Serail Number
CJX2-F 220V 380V 660V without  bar with bar without bar
1000Lc 1000 350 600 980 41 50 0475
1250Lc 1250 430 750 1230 43 54 0476
1450Lc 1450 500 870 1430 55 68 0477
1700Lc 1700 585 1000 1650 59 74 0478
2100Lc 2100 730 1250 2050 63 80 0479
2600Lc 2600 870 1500 2460 83 106 0480
3200Lc 3200 1090 1890 3100 103 138 0481

ac contactor switch mounting dimension drawing

ac contactor dimension photo

Contactor auxiliary switch for 1300 to 3200A 3 pole ac contactor

Product model Contactors Interlock Model Mounting bar Model Fitting model
CJX2-F Inter-locking vertical fitting bar horizontal fitting bar
1000Lc 1000L (2uits) ZRJSA ZRDL10088 ZTJG9743 ZTJG9743
1250Lc 1250L (2uits) ZRJSA ZRDL12588 ZTJG9743 ZTJG9743
1450Lc 1450L (2uits) ZRJSA ZRDL14588 ZTJG9743 ZTJG9743
1700Lc 1700L (2uits) ZRJSA ZRDL17088 ZTJG9743 ZTJG9743
2100Lc 2100L (2uits) ZRJSA ZRDL21088 ZTJG9743 ZTJG9743
2600Lc 2600L (2uits) ZRJSA ZRDL26088 ZTJG9767 ZTJG9736
3200Lc 3200L (2uits) ZRJSA ZRDL32088 ZTJG9767 ZTJG9736
  • Components are set to have center-center distance of 580mm by default.

  • Optional defualt components have center to center distance of 580mm

  • Not part of products, supply along with products, need to be installed by users. Contactors could be fixed on two vertical fitting bars(100-2100Lc) or three vertical bars (2600-3200Lc) or four horizontal fittings bars before final installation, or contactors could be fixed directly on fitting rack withou fitting bars